OUR STORY
Complete solution for wall thickness measurement directly on the machine tool
The RWP20.50-G-UTP ultrasonic touch probe makes it simple to automatically measure the thickness of the walls of larger parts directly on the machine tool, resulting in significantly faster inspections and enhanced data capture.
Measuring the wall thickness of parts manually is a time-consuming process that generates machine tool down-time. The RWP20.50-G-UTP ultrasonic touch probe transforms the procedure by using ultrasound to automatically measure wall thickness within the machine tool installation.
Supported by dedicated thickness measurement software, the RWP20.50-G-UTP is compatible with the control software for Siemens, Heidenhain and Fanuc tooling machines, making it easy to capture and visualise measurement data directly on the shop floor and to export it for use in other programs.
Integrating Hexagon’s robust, proven radio-wave technology, the RWP20.50-G-UTP operates in the 2.4GHz frequency range. Like other probes from Hexagon, the RWP20.50-G-UTP has a robust, modular design and can be converted into a dimensional or temperature probe simply by changing the measuring unit, opening it up to a wider range of applications integrated into the machine tool. And in contrast to other ultrasonic solutions, the RWP20.50-G-UTP works without any coupling fluids, which simplifies operations and helps keep parts cleaner.
Extend the possibilities of your machine tool with the RWP20.50-G-UTP ultrasonic measurement solution for thickness measurements on machine tools.
Transmission Frequency | 2400-2483,5 MHz (2,4GHz) |
Transmission/Reception Range | Up to 18 m |
Power supply | 1x 9 V battery, block, 6LR61, Lithium: 1200 mAh, Alkaline: 550 mAh |
Material | Stainless steel, POM |
Weight without Shank | Approx. 920 g |
Temperature Range | Operation: 10°C - 50°C, Storage: 5°C - 70°C |
Sealing | IP68: EN60529 |
Transmission pulse voltage V50 | -70 V ±10% an 50 Ω |
Pulse rise time tr | 2 to 5 ns |
Pulse fall time tf | 2 to 5 ns |
Pule length td | 100 ±5 ns |
Effective output impedance | 8 Ω ±20% |
Equivalent input impedance | 50 Ω ±18% |
Nominal frequency range | 1,0 to 30 MHz (-3 dB) |
Measurement or pulse repetition frequency | 500 Hz |
Sensing Directions | -Z |
Maximum Stylus Overtravel | -6 mm |
Trigger Force | 10 N |
Recommended Probing Feedrate | 500 mm/min |
Measuring accuracy* | ±10 µm (at 47.10-UTP-D-0.7-9) |
Measuring Range | 0,7 - 9 mm (at 47.10-UTP-D-0.7-9) |
Maximum Battery Life with Lithium Battery at 5% Probing |
Operation: 200 h Standby: 1 year |
* The measuring accuracy depends on the condition (surface finish, surface parallelism) and calibration of the workpiece.
Hexagon'un her sene düzenlenen uluslararası konferansı HxGN LIVE, ilham veren konuşmaları ve sınırsız ağ kurma imkanının yanı sıra görülmesi gereken teknolojileri...
The RWR95.51 radio-wave receiver communicates with radio-wave touch probes in the 2.4 GHz range and can be easily mounted in the machine room.
The m&h IRP25.50-TP temperature probe measures workpiece temperature automatically both before and during machining, enabling greater control of production processes...