RWP20.50-G-UTP Ultrasonic Measurement Solution

Complete solution for wall thickness measurement directly on the machine tool

RWP2050GUTP800x428

The RWP20.50-G-UTP ultrasonic touch probe makes it simple to automatically measure the thickness of the walls of larger parts directly on the machine tool, resulting in significantly faster inspections and enhanced data capture.

Measuring the wall thickness of parts manually is a time-consuming process that generates machine tool down-time. The RWP20.50-G-UTP ultrasonic touch probe transforms the procedure by using ultrasound to automatically measure wall thickness within the machine tool installation. 

Supported by dedicated thickness measurement software, the RWP20.50-G-UTP is compatible with the control software for Siemens, Heidenhain and Fanuc tooling machines, making it easy to capture and visualise measurement data directly on the shop floor and to export it for use in other programs.

Integrating Hexagon’s robust, proven radio-wave technology, the RWP20.50-G-UTP operates in the 2.4GHz frequency range. Like other probes from Hexagon, the RWP20.50-G-UTP has a robust, modular design and can be converted into a dimensional or temperature probe simply by changing the measuring unit, opening it up to a wider range of applications integrated into the machine tool.  And in contrast to other ultrasonic solutions, the RWP20.50-G-UTP works without any coupling fluids, which simplifies operations and helps keep parts cleaner.

Extend the possibilities of your machine tool with the RWP20.50-G-UTP ultrasonic measurement solution for thickness measurements on machine tools.

 

RWP20.50-G-UTP Thickness Measurement Solution

About you
About your company
Innovative measurement technology
Deploying ultrasonic measurement technology directly on the machine tool automates, speeds up and simplifies thickness measurements.

Modular and robust design
The probe can be converted into a regular probe simply by changing the measuring unit. All components are protected to IP68 standards.

No need for any coupling medium
Unlike other ultrasonic solutions, the RWP20.50-G-UTP works without any coupling fluids, which simplifies operations and helps keep parts cleaner.

Extensive report and export functions
Captured data can be viewed in the form of clear reports or can be exported for further use in data bases, tables and statistic software.

Familiar, reliable communication 
RWP20.50-G-UTP communicates with the RWR95.51 radio-wave receiver, which also supports communication to tactile and temperature probes. 
RWP20.50-G – The modular probing system 

The modular, bidirectional probing system RWP20.50 can be used for a range of applications. It can be easily modified by simply screwing in various measuring units. Extensions and cross-probes can both be used.

Reliability and precision are the key to consistently high quality with optimised processing times. Due to the fact that the RWP20.50 can be used as a probe, a temperature sensor and a ultrasonic-probe, the warehousing costs for replacement devices are much lower than for separate device types. This is another advantage, particularly in lean production.

Hexagon’s probes fulfil all requirements in the machine tool in tried and tested fashion. Extreme accelerations, high positioning speeds, constant vibrations, hard tool changes, increased temperatures and coolants pose no problems for Hexagon’s touch probes. The precision mechanics can continue to switch without wear and extremely precisely for years under all these conditions.
   
 Transmission Frequency  2400-2483,5 MHz (2,4GHz) 
 Transmission/Reception Range  Up to 18 m
 Power supply  1x 9 V battery, block, 6LR61,
 Lithium: 1200 mAh, Alkaline: 550 mAh
 Material  Stainless steel, POM
 Weight without Shank  Approx. 920 g
 Temperature Range   Operation: 10°C - 50°C, Storage: 5°C - 70°C
 Sealing  IP68: EN60529
 Transmission pulse voltage V50   -70 V ±10% an 50 Ω
 Pulse rise time tr  2 to 5 ns
 Pulse fall time tf  2 to 5 ns
 Pule length td  100 ±5 ns
 Effective output impedance  8 Ω ±20%
 Equivalent input impedance  50 Ω ±18%
 Nominal frequency range  1,0 to 30 MHz (-3 dB)
 Measurement or pulse repetition frequency  500 Hz
 Sensing Directions  -Z
 Maximum Stylus Overtravel   -6 mm
 Trigger Force   10 N
 Recommended Probing Feedrate  500 mm/min
 Measuring accuracy*  ±10 µm (at 47.10-UTP-D-0.7-9)
 Measuring Range  0,7 - 9 mm (at 47.10-UTP-D-0.7-9)
 Maximum Battery Life with Lithium Battery at
 5% Probing
 Operation: 200 h
 Standby: 1 year

* The measuring accuracy depends on the condition (surface finish, surface parallelism) and calibration of the workpiece.

Radio-wave Probing Systems Brochure

HxGN LIVE

HxGN LIVE is a digital solutions event series providing hands-on, face-to-face access to Hexagon’s latest sensor, software, and autonomous technologies. 

RWR95.51 Radio-Wave Receiver

The RWR95.51 radio-wave receiver communicates with radio-wave touch probes in the 2.4 GHz range and can be easily mounted in the machine room.

m&h Temperature Probe IRP25.50-TP

The m&h IRP25.50-TP temperature probe measures workpiece temperature automatically both before and during machining, enabling greater control of production processes...